GB ∅12 E-Lock
GB ∅12 charging socket actuator (e-lock): 12 VDC, 400 ms actuation, ≥30 N push-pull, 6.2 mm stroke, IP67, 60,000 cycles.
Details ansehen →
GB E-Lock (Push-Rod)
GB front push-rod e-lock: no lanyard, front push-rod design; 12 VDC, 300 ms actuation, ≥35 N push-pull, stroke 6.2/7.5 mm, IP67, 60,000 cycles.
Bekannte Parameter dieses Typs; als "Referenz" gekennzeichnete Werte sind branchenüblich – die technische Vereinbarung hat Vorrang.
| Parameter | Spezifikation |
|---|---|
| Operating temperature | -40 °C to 85 °C |
| Rated current | Motor ≤1.5 A; signal switches ≤0.1 A |
| Stall current / time | Motor ≤2 A (12 V); stall time ≤1 min |
| Actuating time | 300 ms (12 VDC) |
| Actuator push-pull | ≥35 N (12 VDC) |
| Emergency release | ≤20 N (front push-rod, no lanyard) |
| Stroke | 6.2 mm or 7.5 mm |
| Modular design | Connector interface / no lanyard required |
| Parameter | Spezifikation |
|---|---|
| Rated voltage | 12 VDC (operating 9–16 VDC) |
| Protection class | IP67 (static) |
| Durability | 60,000 cycles |
| Stall time | ≤1 min |
Referenzwerte basieren auf öffentlichen Normen (GB/T 20234, IEC 62196, IEC 60529, ISO 26262 u. a.) und dienen nur der Auswahl – sie sind keine Abnahmegrundlage.